Organise filter dimensions, required classification, housing, seal and test-document requirements without relying on a product name alone.

SKYRO product guide · Updated 27 Oct 2026

Start with the specified filter requirement

Identify the filtration stage and the classification written in the project specification. SKYRO lists pre-filters, fine filters and several HEPA product configurations. Use the exact product reference alongside the required classification so a familiar name does not replace the technical requirement. For replacement work, photograph the installed label and record any order reference. If the label is missing or unreadable, say so and request clarification rather than assigning an assumed grade.
Illustrative application for HVAC filter and HEPA enquiry guide
Illustrative HVAC application. Confirm product details with the SKYRO team.

Record the housing and seal interface

Measure width, height and depth with units, then distinguish the filter dimensions from the housing opening. Include the frame requirement, installation orientation and access direction. For minipleat HEPA products, identify whether the specification calls for a gasket seal or gel seal and attach the housing-interface drawing. Mark the seal position and relevant locating details shown by the designer. Similar external dimensions do not by themselves confirm that a replacement will fit or seal as intended.

Request the evidence needed for review

Include design airflow and the product data or test documentation required by the project professional. State whether documentation must identify individual units, a proposed configuration or another defined scope. Ask for the information that will accompany the quotation and supply so it can be reviewed before purchase. The catalogue name Super HEPA Filter does not establish a particular efficiency class. Keep acceptance criteria, installation checks and any site testing with the responsible project team.

Before you contact SKYRO

  • Record the filter type and specified classification.
  • Label filter and housing dimensions separately.
  • Identify frame, seal type, seal position and access direction.
  • Attach airflow requirements, drawings and existing label photographs.
  • List the product data and test documentation required for review.

Discuss your product requirements.

Share your product schedule, dimensions, quantities and project location. Attach the relevant drawings or BOQ privately through the enquiry form.

Connect with the SKYRO team ↗
BUYER QUESTIONS

Useful answers before you enquire.

Does the name HEPA confirm the required efficiency class?
Ask for the exact classification and applicable test evidence for the proposed filter. Match these to the project specification before confirming the selection.
Are gasket-seal and gel-seal filters interchangeable?
Do not assume they are. Share the housing-interface drawing and specified seal arrangement so compatibility can be checked by the project team.
Which details help identify a replacement filter?
Provide the label photograph, filter dimensions, housing details, seal arrangement and previous order reference where available. Include the current specification if it has changed.
What does Super HEPA Filter mean in the catalogue?
It is a listed product name. Request its specific classification, configuration and supporting documentation instead of inferring a grade from that wording.
Should maintenance access be included in the enquiry?
Yes. Show the removal direction and available access space, and ask the project team to confirm the proposed housing and replacement arrangement.